Learn more about our scanners at: https://joescan.com

Page tree
Skip to end of metadata
Go to start of metadata

You are viewing an old version of this page. View the current version.

Compare with Current View Page History

« Previous Version 16 Next »

JS-25 scanners electrical and cable specs.

JoeScan Cables Guide

Click here to download the self contained JoeScan scanner cable specifications guide. 

Input Specifications

The current JS-25 scanners have two connectors: an LTW Industrial Sealed Ethernet, and a iConn 8-conductor circular sealed connector. The 8-conductor connector is used to supply power as well as encoder and synchronization signals to the JS-20 scanner.

The encoder inputs are RS-422 5-V differential signals. They support encoder rates up to a maximum of 100,000 pulses per second.

The Start Scan input signal can be driven by either RS-422 5V differential, 5V push pull, or open collector outputs.  For 5V push-pull and open collector operation, the input should be to the StartScan+ signals, and the StartScan- should be left floating. The Start Scan signal is edge triggered, and by default triggers on a falling edge. The StartScanTriggerOnHigh parameter reverses this, and causes the scanners to trigger on a rising edge.

8-Wire Pinout

JS-25 scanners are generally connected with our standard 8 wire cable. Alpha 2643C or an equivalent cable is suggested.

 

Table 2. Alpha 2643C / EN-3 / 8-Wire Diagram
Wire ColorEN-3 PinFunction
White1Encoder B-
Green2Encoder B+
White/Black3Start Scan-
White/Red4Start Scan+
White/Yellow5Encoder A-
White/Green6Encoder A+
Black7Ground
Red8+24VDC

 

 

  • No labels